20
How the fault shows up?
Through codes automatically shown on the display.
Here follows the list including some hints to solve them.
NOTE: The code of the alarms can change in case of particular functions or client
needs
Alarm
code
Description What to do
21
Boom length sensor
total reading higher
than the maximum
value
• Verify that the cable or the connector wiring is not
open
If the alarm persists, please, contact Technical
Assistance :
• Verify the length transducer integrity
18
Table charts not
available..
The operating
condition selection is
missing
•Please, select the operating mode in use and
confirm it.
20
Group
Alarm.Configuration
errore
•Please, select the operating mode in use and
confirm it.
6
Boom length sensor 1
reading lower than the
minimum value
• Verify that the wiring and the connectors are not in
short circuit
If the alarm persists, please, contact Technical
Assistance:
Verify the length transducer integrity
7
Boom length sensor 1
reading higher than the
maximum value
• Verify that the cable or the connector wiring is not
open
If the alarm persists, please, contact Technical
Assistance :
• Verify the length transducer integrity
E01
RADIUS
MIN
The boom’s angle has
overtaken the
maximum value
• Lower the boom
E02
RADIUS
MAX
This message appears
when the boom is
positioned in a way
that, referring to the
load charts, there isn’t
any load charts table
applicable
•Lift or close the crane boom until a load chart table
can be applied.