3. SPECIFICATIONS
3-1 General specifications
• Measurement method: Digital, triaxial measurement.
• Directional characteristic: Isotropic, triaxial.
• Measurement range selection: One continuous range.
•
Display resolution
: 0.1mV/m, 0.1
µ
A/m, 0.1
µ
W/m
2
, 0.001
µ
W/cm
2
• Setting time: Typically 1s (0 to 90% of measurement value).
• Display refresh rate: Typically 0.5 seconds
• Display type: Liquid-crystal (LCD), 4 digit.
• Audible alarm: Buzzer.
• Units: mV/m, V/m, µA/m, mA/m, µW/m
2
, mW/m
2
, W/m
2
,
µW/cm
2
, mW/cm
2
• Display value: Instantaneous measured value, maximum
value or maximum average value.
• Alarm function: Adjustable threshold with ON/OFF.
• Calibration factor CAL: Adjustable.
• Manual data memory and read storage: 99 data sets.
• Rechargeable lithium-ion battery: 3.6V, 1940mAh
• Battery charging time: Approx. 3 hours
• Battery operation time: Approx. 10 hours
• Auto power off: 5 minutes.
• Operating temperature range: 0
℃
to +50
℃
• Operating humidity range: 25% to 75%RH
• Storage temperature range: -10
℃
to +60
℃
• Storage humidity range: 0% to 80%RH
• Dimensions: Approx. 67(W)×60(T)×247(L)mm.
• Weight (including battery): Approx. 250g
• Accessories: Instruction manual, Rechargeable Lithium-ion
battery, Carrying case, AC adaptor (DC 5V 1.5A).