EasyManuals Logo

Texas Instruments 28xxx User Manual

Texas Instruments 28xxx
119 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
www.ti.com
Action-Qualifier Submodule Registers
Figure 4-9. Action-Qualifier Output A Control Register (AQCTLA)
15 12 11 10 9 8
Reserved CBD CBU
R-0 R/W-0 R/W-0
7 6 5 4 3 2 1 0
CAD CAU PRD ZRO
R/W-0 R/W-0 R/W-0 RW-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 4-9. Action-Qualifier Output A Control Register (AQCTLA) Field Descriptions
Bits Name Value Description
15-12 Reserved Reserved
11-10 CBD Action when the time-base counter equals the active CMPB register and the counter is
decrementing.
00 Do nothing (action disabled)
01 Clear: force EPWMxA output low.
10 Set: force EPWMxA output high.
11 Toggle EPWMxA output: low output signal will be forced high, and a high signal will be forced low.
9-8 CBU Action when the counter equals the active CMPB register and the counter is incrementing.
00 Do nothing (action disabled)
01 Clear: force EPWMxA output low.
10 Set: force EPWMxA output high.
11 Toggle EPWMxA output: low output signal will be forced high, and a high signal will be forced low.
7-6 CAD Action when the counter equals the active CMPA register and the counter is decrementing.
00 Do nothing (action disabled)
01 Clear: force EPWMxA output low.
10 Set: force EPWMxA output high.
11 Toggle EPWMxA output: low output signal will be forced high, and a high signal will be forced low.
5-4 CAU Action when the counter equals the active CMPA register and the counter is incrementing.
00 Do nothing (action disabled)
01 Clear: force EPWMxA output low.
10 Set: force EPWMxA output high.
11 Toggle EPWMxA output: low output signal will be forced high, and a high signal will be forced low.
3-2 PRD Action when the counter equals the period.
Note: By definition, in count up-down mode when the counter equals period the direction is defined
as 0 or counting down.
00 Do nothing (action disabled)
01 Clear: force EPWMxA output low.
10 Set: force EPWMxA output high.
11 Toggle EPWMxA output: low output signal will be forced high, and a high signal will be forced low.
1-0 ZRO Action when counter equals zero.
Note: By definition, in count up-down mode when the counter equals 0 the direction is defined as 1
or counting up.
00 Do nothing (action disabled)
01 Clear: force EPWMxA output low.
10 Set: force EPWMxA output high.
11 Toggle EPWMxA output: low output signal will be forced high, and a high signal will be forced low.
100 Registers SPRU791D November 2004 Revised October 2007
Submit Documentation Feedback

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments 28xxx and is the answer not in the manual?

Texas Instruments 28xxx Specifications

General IconGeneral
BrandTexas Instruments
Model28xxx
CategoryAccessories
LanguageEnglish

Related product manuals