GAPRole Central Role API
bStatus_t GAPCentralRole_TerminateLink (uint16 connHandle);
Terminates an existing connection.
Parameters connHandle - connection handle of link to terminate or...
0xFFFE: cancel the current link establishment request or...
0xFFFF: terminate all links
Returns SUCCESS: termination has started
bleIncorrectMode: there is no active connection
LL_STATUS_ERROR_CTRL_PROC_ALREADY_ACTIVE: terminate procedure already
started
bStatus_t GAPCentralRole_EstablishLink(uint8 highDutyCycle, uint8 whiteList, uint8
addrTypePeer, uint8 *peerAddr)
Establishes a link to a peer device.
Parameters highDutyCycle - TRUE to high duty cycle scan, FALSE if not
whiteList - determines use of the white list
addrTypePeer - address type of the peer device:
peerAddr - peer device address
Returns SUCCESS: link establishment has started
bleIncorrectMode: invalid profile role.
bleNotReady: a scan is in progress.
bleAlreadyInRequestedMode: cannot process now.
bleNoResources: too many links.

Table of Contents

Other manuals for Texas Instruments CC2540DK-MINI

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments CC2540DK-MINI and is the answer not in the manual?

Texas Instruments CC2540DK-MINI Specifications

General IconGeneral
BrandTexas Instruments
ModelCC2540DK-MINI
CategoryMicrocontrollers
LanguageEnglish

Related product manuals