EasyManuals Logo

Texas Instruments Serial Programming Adapter MSP430 User Manual

Texas Instruments Serial Programming Adapter MSP430
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
Command Line Options
2-10
2.3 Command Line Options
2.3.1 General Definitions
0: Off 1: First selectable option
1: On 2: Second selectable option
3: Third selectable option
The PRGS430.ini file options are used if they are not specified in the command
line. The command line option overwrites the .ini file options.
The program exits automatically if a command is passed via the command line
and the command was executed. There is only a small status window opened
during the execution.
Only one command identifier (/cmd:) is allowed within the command line.
Otherwise, the execution is canceled and an error is returned.
If an error in the command line parameter is detected, the program exits with
an error message.
The filename may also contain a path. If special characters are used, the string
has to be inside quotes (for example, \\server\adt430\PRG files\test.txt).
If an error is detected within the filename, the operation is canceled and an
error is returned.
Table 2−3.Command Line Options
Commands:
/cmd:PRG Program command
/cmd:VFY Verify command
/cmd:ERS Erase command
/cmd:CHK Erase check command
/cmd:READ Read out command
/cmd:RST Reset command
/cmd:BLOW Blow fuse command
Options:
/COM:x Specifies the serial port: /COM:1, /COM:2, /COM:3, or /COM:4
/BR:xxxxxx Sets baud rate to be used: 9600/19200/38400/57600/115200, e.g., /BR:57600
/Dev: Selects the device according to the name in the device.cfg file, e.g., /Dev:MSP430F1121
/SVolt:x.x Selects supply voltage MSP_VCC of the programming adapter. The voltage is supplie
d
between GND and MSP VCC, e.g., /Svolt: 3.0.
/SVolt:x.x
Selects supply voltage MSP_VCC of the programming adapter. The voltage is supplied
between GND and MSP VCC, e.g., /Svolt: 3.0.
/SVoff:{0,1} Switches off supply voltage MSP_VCC after execution
0: Disable (do not switch off)
1: Enable (switch off)
filename Specifies name of the object file to be programmed or verified
/FILE filename (Second way to define the filename − space separated)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments Serial Programming Adapter MSP430 and is the answer not in the manual?

Texas Instruments Serial Programming Adapter MSP430 Specifications

General IconGeneral
BrandTexas Instruments
ModelSerial Programming Adapter MSP430
CategoryAdapter
LanguageEnglish

Related product manuals