User Functions Menu Premier 412/816/832 Master User Manual
12 INS141-8
Service Faults Displayed on LED Keypads
Light Fault Condition
1
General Warnings
Press (Key 1) to view the warning, lights 1-5 will
indicate the following:-
1 = AC Fail
2 = Arming Fob has Low Battery
3 = Soak Test Active
2 Telephone Line Fault
3 2-Wire Smoke Alarm
4
Box Tamper & Auxiliary Input:
Press to view type, lights 1 - 8 indicate:
1 = Box Tamper 4 = Auxiliary Tamper *
2 = Auxiliary Tamper 5 = Bell Tamper *
3 = Auxiliary PA 6 = Radio Plus Tamper
7 = Low Fob Battery 8 = User Code Tamper
* = UK Bell Module
5 Date or Time Lost
6
Zone Tamper/Trouble
Press to view zone number
7
Keypad Tamper/Removed
Press to view keypad number
8
Equipment Faults
Press to view fault type, lights 1 - 8 indicate:
1 = Output 1 Fault
2 = Output 2 Fault
3 = Siren/Bell Fault
4 = 2-Wire Smoke Sensor Fault
5 = Auxiliary Fuse Failed
6 = Battery Fault
7 = Service Timer/Zone Soak Test Failed
8 = Com Fault or Fail To Communicate
Service Faults Displayed on LCD Keypads
LCD Fault Condition
  AC Fail
   One or more zones on soak test
  1 to continue arming 0 to exit arming
   
Key fob has a low battery (Message
above shown)
   Shown after invalid user code attempts
  Telephone Line Fault
   2-Wire Smoke Alarm
  Box Tamper
  Auxiliary Tamper (Aux Input)
  Auxiliary Tamper (UK Bell Module)
  Bell Tamper (UK Bell Module)
   Auxiliary PA (Aux Input)
  Date or Time Lost
    Zone Tamper/Trouble
   Keypad Tamper/Removed
   Output 1 Fault
   Output 2 Fault
  Siren/Bell Fault
   2-Wire Smoke Sensor Fault
   Auxiliary Fuse Failed
  Battery Fault
  Service Timer/Zone Soak Test Failed
  Com1 Fault or Fail To Communicate
Anti-code Reset
This feature is normally used in the UK where users are not
permitted to reset the panel following a communicated
alarm. However, the user can reset the panel after entering a
unique remote reset number, which is supplied by their
installer or ARC.
To perform an Anti-code Reset, proceed as follows:
  
 
  
  
The ke ypad will display a
randomly generated
4-digit Code.
Press

Enter Access code

1
2
3
C on tac t yo ur AR C /I ns ta lle r t o o b tain a An ti-c od e R es e t
nu m be r.
Tel No.__________________________________________
E nte r the An ti-c o d e R e s et nu mb e r g iven to y o u b y y o ur
ARC /Installer
I f the code is ac cepted, the keypa d will s ound a n
acce ptance tone a nd the system will res e t and return to
th e n or mal d is arm e d s tate .
