Premier 640 Quick Reference Guide Programming Quick Reference
INS296 9
Key Output Group Outputs Types
!#
Not Used: Press
"
to accept
$#
System:
!
Select output number or use
(
to search,
"
to accept
#
!
00: ATS Path Fault 19: UDL Call Active
!
37: Custom 4 Stage AB
#
01: Mains Power Off 20: UDL Enabled
!
38: Com 1 Fault
#
02: Aux Fuse Fault 21: Confirmed Alarm 39: Com 2 Fault
#
03: Bell Tamper 22: Custom 1 Stage A 40: Com3 Fault
#
04: Auxiliary Tamper 23: Custom 1 Stage B 41: Com 1 No Signal
#
05: Panel Lid Tamper 24: Custom 1 Stage AB 42: Com 2 No Signal
#
!
06: Engineer Working 25: Custom 2 Stage A 43
!
Com 3 No Signal
#
!
07: Confirm Devices 26: Custom 2 Stage B 44 Com Port Fault
#
!
08: Service Required 27: Custom 2 Stage AB 45: Radio Jamming
#
!
09: Bell Fuse Blown 28: Radio-Pad Failed 46:
!
Radio RX Tamper
#
!
10: Battery Fault
!
30: No Radio Signal 47: Detector Test
#
!
11: Battery Test On
!
31: Radio-Pad Lost 48: ATS Remote Test
#
!
12: Courtesy Light
!
30: No Radio Signal 49: No ATS Available
#
!
13: System Open
!
31: Radio-Pad Lost 50: CIE Fault
#
!
14: Fully Arm
!
32: Custom 3 Stage A 51: PSU Fuse Blown
#
!
15: Digi Failed
!
33: Custom 3 Stage B 52: PSU Battery Flt
#
!
16: Digi Successful
!
34: Custom 3 Stage AB 53 WD Test Active
#
!
17: Digi Active
!
35: Custom 4 Stage A
#
!
18: UDL Lockout 36: Custom 4 Stage B
)#
Area: Select output number or use
(
to search, enter Area Profile number,
"
to accept
#
00: Alarm 23: Part Armed! 46: Time Arming
#
01: Guard 1 Alarm 24: Part Arming! 47: 1
st
Code Entered
#
02: Guard 2 Alarm 25: Force Armable! 48: 2
nd
Code Entered
#
03: Entry Alarm 26: Force Armed! 49: Area Secured
#
04: Confirmed Alarm 27: Arm Fail! 50: Part Armed 1
#
05: 24Hr Audible 28: Bell SAB! 51: Part Armed 2
#
06: 24Hr Silent 29: Bell SCB! 52: Part Armed 3
#
07: 24Hr Gas 30: Strobe! 53: Custom Alarm
#
!
08: PA Audible 31: Switch 12 Volts! 54: Zone Warning
#
09: PA Silent 32: Detector Reset! 55: Arm Fail Warning
#
10: Duress 33: Walk Test Active! 56: Forced Entry
#
11: Fire Alarm! 34: Zones Omitted 57: Zones Locked Out
#
12: Medical 35: 24Hr Zones Omit 58: All Armed
#
13: Auxiliary Alarm! 36: Reset Required 59: Auto Arm Disable
#
14: Tamper Alarm! 37: Door Strike 60: Armed / Alarm
#
15: Alarm Abort! 38: Chime Mimic 61: Intruder Alarm
#
16: Ready! 39: Chime Enabled 62: Speaker Mimic
#
17: Entry Mode! 40: DK First Knock 63: Full Arm/Exit
#
18: 2
nd
Entry Mode! 41: BP First Knock 64: Detector Fault
#
19: Exit Mode! 42: On Test 65: Detector Mask
#
20: Entry/Exit Mode! 43: Test Fail 66: Fault Present
#
21: Armed! 44: Internal Alarm 67: LED Control
#
22: Full Arm! 45: Auto Arming 68: Full Arm Entry
*#
Zone: Use
$
-
%
to enter a zone number or use
(
to search,
!
-
,
to select a zone
output type,
"
to accept
#
!
Mimic
)
Alarm
+
MimicLatch
#
$
MimicArm
*
Tamper
!
,
Omitted
+#
User: Use
$
-
%
to select a User code or use
(
to search,
"
to accept
,#
Control Timer: Use
$
-
%
to select a Control Timer,
"
to accept
-#
PC Control: Use
$
-
%
to select a PC Control,
"
to accept
.#
Door Control: Use
$
-
%
to select a Door Control,
"
to accept
%#
X-10: Use
$
-
%
to select a an X-10 Output,
"
to accept

Other manuals for Texecom PREMIER 640

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texecom PREMIER 640 and is the answer not in the manual?

Texecom PREMIER 640 Specifications

General IconGeneral
BrandTexecom
ModelPREMIER 640
CategorySecurity System
LanguageEnglish

Related product manuals