Page #1 background image
8 COVERAGE AT 2m
7 MOUNTING HEIGHT AND
SETTINGS
6 ANGLING THE DETECTOR 5 COVERAGE AND PICK-UP
4
3 STANDARDS & APPROVALS 2 ENVIRONMENTAL 1 PHYSICAL
!
!
-35°C (-31°F) to +60°C (+140°F)
125g (4.5oz) approx.
-35°C (+31°F) to +55°C (+131°F)
63mm
(2.5)
40mm
(1.6)
90mm
(3.6)
2.5mm (0.1) ABS
QUALITY ASSURANCE
WARRANTY
10 year replacement warranty.
Document Ref: PCIR/EU/1.0-3
© 2003-2009 Texecom Ltd
The Prestige Compact IR/QD is protected by UK & International Registered Design. Registered Design Number: 3008617
Certificate Number: FM 35285
INS 244-6
Passive Infrared Detector
15m
50
15m
50
90˚
The Prestige Compact IR/QD is designed to detect the movement of an
intruder and activate an alarm control panel. As the Prestige Compact IR/QD is
not a complete alarm system, but only a part thereof, Texecom cannot accept
responsibility or liability for any damages whatsoever based on a claim that the
Prestige Compact IR/QD failed to function correctly.
All specifications are measured at 20˚C (68˚F). Due to our policy of continuous
improvement Texecom reserves the right to change specification without prior
notice.
TAMPER
0V
ALARM
JP3
JP4
LED OFF
DO NOT TOUCH
0.3 - 3.0m/s
PULSE COUNT
1
2
3
1 - 10ft/s
EOL RESISTOR HEADERS
(See Section 14)
EOL
Resistance
<24VDC, 50mA
23Ω, (N/C)
<24V
DC, 50mA
(N/C)
Quiescent Current=
9mA @ 12V
DC
Max Current=
9mA @ 12V
DC
Alarm
Resistance
Alarm Standard:
EN 50131 Grade 2 Environmental Class II.
Detector Standard:
EN 50131-2-2 Grade 2 Environmental Class II.
EMC:
Independently certified to BS EN 50130-4 : 1996.
A1 : 1998 A2 : 2003.
RF Immunity:
No false alarms from 80GHz to 1GHz at 10V/m.
1GHz to 2GHz at 10V/m. BS EN 61000-4-3 : 1997.
Electrostatic
Discharge:
No false alarms up to 8kV.
BS EN 61000-4-2 : 1995.
Fast Transient
Immunity:
No false alarms up to ±4kV.
BS EN 61000-4-4 : 1995.
High Energy
Transient Immunity:
No false alarms up to ±1kV.
BS EN 61000-4-5 : 1995.
Conducted RF
Susceptibility:
No false alarms at 10Vrms.
BS EN 61000-4-6 : 1996.
Conducted &
Radiated Emissions:
EN 55022 : 2006 Class B.
EN 61000-6-3 : 2007
MADE IN
ENGLAND
Quad Element Detector
INSTA L L A T ION INST RUCT IONS
OC 03
LED ON
Prestige
Compact IR
only
Question and Answer IconNeed help?

Do you have a question about the Texecom PrestigeCompact IR and is the answer not in the manual?

Texecom PrestigeCompact IR Specifications

General IconGeneral
Coverage Angle90°
Power Supply9-16VDC
TypePIR Detector
Temperature Range-20°C to +55°C
Operating Temperature-20°C to +55°C

Summary

Physical Specifications

Environmental Conditions

Standards and Approvals

Warranty Information

Coverage and Detection Area

Detector Angling

Mounting Height and Settings

Coverage at 2 Meters

Volumetric Coverage Pattern

Mounting Options

Wiring Instructions

Location Selection

EOL Resistor Jumper Links

EOL Jumper Link Usage Examples

Examples of EOL jumper link usage for Texecom Premier Panels, showing values for JP1 and JP2.

Dual EOL Detector Configuration

Diagram illustrating the connection of two Dual End-of-Line (DEOL) detectors to a single zone.

Detector Knockouts

Ceiling Mount Bracket

Wall Mount Bracket

Mounting Without Brackets