EasyManuals Logo
Home>Texmo Industries>Water Pump>TARO TSM ZR Series

Texmo Industries TARO TSM ZR Series User Manual

Default Icon
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
Warning
Switch OFF the power before working on electrical lines
Caution
Do not use this pump for pumping liquid exceeding 33
0
C as this may lead to
product failure
Warning
Do not switch ON the pump if there is any human contact with the pumped
medium. If any electrical leakage occurs, this could be fatal
Caution
The Openwell Submersibles has water lubricated journal and thrust bearings
and therefore shall not be run dry. Starting of the Openwell Submersibles
without water must be strictly avoided as it will cause damage to the
bearings. Fill with pure drinking water
Note
During monsoons, the pump will run with higher flooded suction resulting in
the pump running with higher discharge. This results in increase in the current
drawn being higher than that specified on the name plate. Fit a gate valve in
the delivery line to throttle the discharge till the current is lower than that
specified on the name plate
Caution
Ensure proper direction of rotation of the pump on powering up.
Operation Precautions
Note
Check the bottom of the well. In case there is mud accumulated at the well
bottom, de-silt the well
Note
Periodically de-silt the bottom of the well so that the Openwell Submersibles
rests on the rocky bottom
OMOW001A 13 2020.01

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texmo Industries TARO TSM ZR Series and is the answer not in the manual?

Texmo Industries TARO TSM ZR Series Specifications

General IconGeneral
BrandTexmo Industries
ModelTARO TSM ZR Series
CategoryWater Pump
LanguageEnglish

Related product manuals