Step 8
Place Pump in Pre-Filter
Position the pump into the bottom section of the
pump pre-lter cage by aligning the discharge and
power cord with the notches on the cage.
Step 9
Secure Pre-Filter Cage
Align and place the top half of the pre-lter cage
over the pump. Holding the two sections of the cage
together, ip the SolidFlo™ G2 Pump over and reinstall
the 2 screws.
MAINTAINING YOUR SOLIDFLO
G2 PUMP:
TROUBLESHOOTING :
Pump does not turn on:
• Check that the power cord is connected.
• Check to see if the circuit breaker is tripped.
• GFCI may be faulty.
• Check power cord for damage.
• Check for blockage on pump intake housing.
Pump turns on and then shuts o:
• Verify pump is completely submerged for proper cooling.
• Check for debris clogging the pump intake housing.
Verify if using an extension cord that it is of the proper rating for the pumps
electrical requirements.
Reduced water ow:
• Check for debris clogging the pump intake housing.
• Verify that water level is not low.
• Check plumbing for clogs.
• Verify correct diameter tting and appropriate length of tubing is being used.
15425 Chets Way | Armada, MI 48005