1
SIMPLEXA 601 top
6010140
307561 01
Time switch
EN
1. Basic safety information
Danger of death through electric shock or fire!
¾ Installation should only be carried out by a
qualied electrician!
WARNING
The device is designed for installation on DIN top hat
rails (in accordance with EN 60715)
The device corresponds to type 1 STU in accordance with
IEC/EN 60730-2-7
2. Proper use
The time switch is used for lighting, ventilation and
ushing applications etc.
Only for use in closed, dry rooms
!
Do not use on safety devices, e.g. escape route doors, re
safety equipment etc.
Disposal
Dispose of device in environmentally sound manner
3. Installation and connection
Mounting the time switch
clic
Mount on DIN top hat rails (as dened in EN 60715)
Switched voltage-free
Ensure device cannot be switched on
Check absence of voltage
Earth and bypass
Cover or shield any adjacent live components
Connecting the time switch
C1
1 2 N
N
L
L
L
!
Correct connection (see wiring diagram) required for
smooth function of the zero-cross switching.
4. Device description
Display & buttons
06
12
18
24
MENU OK
OKMENU
Programmed
switching times
Date display
Channel status
On
Off
Time display
Days of the week
from 1 to 7
Display of the active buttons
with the relevant function
Activate display
Open menu
Cancel menu
ESC
(leave menu)
Save
selection
Confirm
selection
¾
Options
are displayed
Question and Answer IconNeed help?

Do you have a question about the Theben SIMPLEXA 601 top and is the answer not in the manual?

Theben SIMPLEXA 601 top Specifications

General IconGeneral
Voltage230 V AC
Switching capacity16 A
Switching capacity at 250 V AC, cos φ = 116 A
Switching capacity at 250 V AC, cos φ = 0.64 A
Shortest switching time1 minute
Storage temperature-20°C to +60°C
Protection classIP20
Type of connectionScrew terminals
MountingDIN rail
Timer channels1
Contact typeChangeover contact
Frequency50 – 60 Hz
ProgramDaily program
Time accuracy± 1 second per day
Operating temperature-10°C to +55°C
Battery backupYes

Summary

Safety, Use, and Installation Procedures

Basic Safety Information and Standards

Key safety warnings, including shock/fire risk, and compliance with standards EN 60715 and IEC/EN 60730-2-7.

Proper Use and Disposal Guidelines

Details intended applications (lighting, ventilation) and restrictions for use in dry rooms and on safety devices, plus disposal advice.

Installation and Connection Details

Instructions for mounting the time switch and connecting it correctly for zero-cross switching.

Device Description

Display and Buttons Overview

Explains the elements of the device display and the function of the navigation buttons (MENU, OK, ESC).

Device Operation and Settings

Initial Setup and Operation

Steps for initial setup, including setting language, date, time, and summer/winter time.

Switching Time Programming

Guides on programming new switching times, including start/end times and days of the week.

Modifying Switching Times

Procedures for modifying or deleting existing switching times for blocks or single days.

Advanced Settings and Control

Switching Program Management

Detailed steps for modifying or deleting programmed switching times for specific days or blocks.

PIN Code and Holiday Settings

Steps to set or manage a PIN code and configure holiday function for specific periods.

Manual and Permanent Switching

How to activate manual control or permanent ON/OFF switching, overriding programmed times.

Technical Data and Contact Information

Technical Specifications

Detailed specifications including operating voltage, frequency, switching capacity, and load ratings.

Company Contact Details

Provides Theben AG's address, phone numbers, hotline, and website for support and inquiries.

Related product manuals