EasyManuals Logo

Thecus N5550 User Manual

Thecus N5550
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #125 background imageLoading...
Page #125 background image
125
ix. Advance options can be setup by pressing the associated button.
Heart Beats Configuration
Item
Description
Keep alive time
The keep alive directive sets the interval between heartbeat
packets. It is specified according to the Heartbeat time syntax.
Dead time
The dead ping directive is used to specify how quickly Heartbeat
should decide that a ping node in a cluster is dead. Setting this
value too low will cause the system to falsely declare the ping
node dead. Setting it too high will delay detection of
communication failure.
This feature has been replaced by the more flexible ping
resource agent in Pacemaker, and should no longer be used.
Warning time
The warn time directive is used to specify how quickly Heartbeat
should issue a "late heartbeat" warning.
Initial dead time
The initial dead parameter is used to set the time that it takes to
declare a cluster node dead when Heartbeat is first started. This
parameter generally needs to be set to a higher value, because
experience suggests that it sometimes takes operating systems
many seconds for their communication systems before they
operate correctly.
UDP port
The udp port directive specifies which port Heartbeat will use
for its UDP intra-cluster communication. The default value for
this parameter is UDP 694 port.
x. Click Apply, the Primary server will prompt the message below and wait
for the Standby server settings to be completed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thecus N5550 and is the answer not in the manual?

Thecus N5550 Specifications

General IconGeneral
RAID levels0, 1, 5, 6, 10, JBOD
Hot-swap drive baysYes
Storage drive capacity0 GB
Supported file systemsext3, ext4, XFS
Storage drive interfaceSerial ATA
Total installed storage capacity0 TB
Number of storage drives installed0
Number of storage drives supported5
Internal memory2 GB
Internal memory typeDDR3
Processor familyIntel Atom®
Number of processors installed1
Wi-FiNo
Data link protocolsTCP/IP/AppleTalk
Ethernet LAN data rates10, 100, 1000 Mbit/s
Maximum data transfer rate1000 Mbit/s
Supported network protocolsSMB/CIFS, HTTP/HTTPS, FTP, NFS v4, AFP
I/O ports1 x mic in 1 x line in 1 x audio out
Networking featuresGigabit Ethernet
Compatible operating systemsWindows 2000/XP/2003/Vista/ 7 UNIX/Linux Mac OS X
Security algorithms256-bit AES
Cables includedAC
FireWire 400FireWire-interface with a data transmission speed of 400 Mbit/s (50MB/s). FireWire is a serial computer bus technology designed as replacement of SCSI and is based on the IEEE 1394 and 1394b standards.
USB 2.0 ports quantity4
Ethernet LAN (RJ-45) ports2
Bundled softwareAcronis True Image Thecus Backup Utility
Display typeLCD
Product colorBlack
Power supply unit (PSU) capacity200 W
Operating temperature (T-T)5 - 40 °C
Operating relative humidity (H-H)0 - 80 %
Sustainability certificatesRoHS
CertificationCE/FCC/C-Tick/VCCI/BSMI VMware, Citrix, WEEE
Weight and Dimensions IconWeight and Dimensions
Depth240 mm
Width190 mm
Height230 mm

Related product manuals