POOL+ MANAGER App A2 - User Manual v1.0 17
6.4
HEATING
CONTINUED
HEAT PUMP ON
OFF
Use the or buttons to highlight either ON or OFF.
Enter On to enable the controller to run the Heat Pump or OFF to disable the heater.
Press the Enter button to accept.
Once you have accepted an option the controller will display:
GAS HEATER ON
OFF
If you select ON, the controller will then display:
GAS HEATER
COOL DOWN XXMIN
This is the controller asking how many minutes you would like the filtration pump to
run for once the Heater has stopped heating. Use the or buttons to increase or
decrease the amount of time.
The range of time for the Cool Down is 00Mins to 59Mins.
Note: This function is here to help prolong the life of a Gas Heater. 5Mins is an
acceptable minimum but the time can be extended if so desired.
Once you have selected the timeframe you would like for the Gas Heater COOL DOWN,
the controller will move you onto the next option.
If you select OFF, the controller will move you onto the next option and display:
HEATING PUMP
SPEED X
Use the or buttons to select which pre-set speed you would like, and press Enter.
Once you have selected the pump speed the controller will exit you to the Installer
Setup Menu.