Parameter Meaning
CURRENT Displays the current consumption in Amperes. The set value for MAX CURRENT is shown in brackets.
Only appears if CURRENT LIMITER is selected in the Service menu.
DISCH. PIPE Shows the temperature at the discharge pipe sensor.
SUCTION GAS Shows the temperature of the suction gas.
EVAP. PRESSURE Shows the pressure of the suction gas pipe. Measured in bar atmospheric pressure, bar (a).
DEFR SENSOR Shows the temperature of the defrost sensor.
7.9 Exit test operation
Set the value for MANUAL TEST to 0.
7.10 Insulate the piping
When the manual testing is finished, do a final check for leaks and insulate the piping.
Caution Make sure that pipes transporting cold water are insulated to prevent condensation damage.
Commissioning Atec