TK 50045 (Rev. 16, 01-2018)
Ingersoll Rand Company Ltd. • Monivea Road • Mervue, Galway • Ireland
Maintenance Manual
Trailer Units
SL-100
SL-200
SL-300
SL-400
SL-TCI
SL-100e
SL-200e
SL-400e
SPECTRUM SL
SLX-100
SLX-200
SLX-300
SLX-400
SLX SPECTRUM
SLX Whisper
SLX Ferry
SLXe-100
SLXe-200
SLXe-300
SLXe-400
SLXe SPECTRUM
SLXe Whisper
SLXe-300 Whisper Pro
SLXe SPECTRUM Whisper
Pro
SLXi-100
SLXi-200
SLXi-300
SLXi-400
SLXi Spectrum
SLXi-300 Whisper Pro
SLXi SPECTRUM Whisper
Pro

Table of Contents

Other manuals for Thermo King SLXi-300

Questions and Answers

  • L
    Lynn MartinAug 7, 2025
    What to do if my Thermo King Automobile Accessories unit did not start automatically?
    • R
      Robert RodriguezAug 7, 2025
      If the unit did not start automatically, determine the cause for not starting. Correct as required. Continue monitoring return air temperature until reading is within desired temperature range of the setpoint.
  • J
    Jennifer TannerAug 14, 2025
    What to do if the Thermo King Automobile Accessories return air temperature is not within the desired range?
    • A
      Amanda WardAug 14, 2025
      If the return air temperature is not within the desired range, several factors could be the cause. First, review the load log history for above-temperature load records to ensure the cargo compartment was properly pre-cooled and consider the length of time on the road. If the unit is in defrost or has just completed a defrost cycle, monitor the return air temperature after the defrost cycle is completed to see if the temperature returns to the desired temperature range of the setpoint. Also, the evaporator may be plugged with frost, so initiate a manual defrost cycle. Finally, inspect the unit and cargo compartment to ensure the evaporator fans are working properly and that air circulation is not blocked by improper loading or shifting cargo.
  • A
    April WrightAug 21, 2025
    Why is my Thermo King Automobile Accessories not cooling to the set temperature?
    • S
      Steven MurilloAug 21, 2025
      Several factors can prevent your Thermo King unit from cooling to the set temperature. The unit may have a low refrigerant charge; check the receiver tank sight glass for refrigerant level. If fluid is not showing, a competent refrigeration technician is required to add refrigerant or repair the system. Improper air circulation in the cargo compartment may also be the reason. Inspect the unit and cargo compartment to determine if the evaporator fans are working properly circulating the air. Poor air circulation may be due to improper loading of the cargo, shifting of the load, or fan belt slippage. Correct as required.
  • R
    Richard WilsonAug 29, 2025
    Why my Thermo King Automobile Accessories multi-temp unit can't cool the entire trailer?
    • M
      Marcus JohnsonAug 29, 2025
      A multi-temperature unit may not have the cooling or heating capacity to maintain a specific temperature range throughout an entire trailer if it is being used to cool/heat a single temperature load.

Thermo King SLXi-300 Specifications

General IconGeneral
BrandThermo King
ModelSLXi-300
CategoryRefrigerator
LanguageEnglish

Related product manuals