EasyManua.ls Logo

Thermo King SLXi Spectrum - User Manual

Thermo King SLXi Spectrum
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Revision A
September 2018
TTKK 6611445522--22--OOPP--EENN
SLXi-100, 200, 300, 400, SLXi-300 Whisper Pro,
SLXi Spectrum and SLXi Spectrum Whisper Pro
Operator’s Manual

Table of Contents

Other manuals for Thermo King SLXi Spectrum

Questions and Answers

  • D
    deborahhartAug 10, 2025
    What to do if my Thermo King Automobile Accessories unit did not start automatically?
    • J
      James ParsonsAug 10, 2025
      If the unit did not start automatically, determine the cause for not starting. Correct as required. Continue monitoring return air temperature until reading is within desired temperature range of the setpoint.
  • R
    Ricardo MillerAug 18, 2025
    What to do if the Thermo King Automobile Accessories return air temperature is not within the desired range?
    • J
      Joshua PayneAug 18, 2025
      If the return air temperature is not within the desired range, several factors could be the cause. First, review the load log history for above-temperature load records to ensure the cargo compartment was properly pre-cooled and consider the length of time on the road. If the unit is in defrost or has just completed a defrost cycle, monitor the return air temperature after the defrost cycle is completed to see if the temperature returns to the desired temperature range of the setpoint. Also, the evaporator may be plugged with frost, so initiate a manual defrost cycle. Finally, inspect the unit and cargo compartment to ensure the evaporator fans are working properly and that air circulation is not blocked by improper loading or shifting cargo.
  • A
    Ana BarnesAug 25, 2025
    Why is my Thermo King Automobile Accessories not cooling to the set temperature?
    • J
      Justin LopezAug 26, 2025
      Several factors can prevent your Thermo King unit from cooling to the set temperature. The unit may have a low refrigerant charge; check the receiver tank sight glass for refrigerant level. If fluid is not showing, a competent refrigeration technician is required to add refrigerant or repair the system. Improper air circulation in the cargo compartment may also be the reason. Inspect the unit and cargo compartment to determine if the evaporator fans are working properly circulating the air. Poor air circulation may be due to improper loading of the cargo, shifting of the load, or fan belt slippage. Correct as required.
  • M
    Marissa SheltonSep 1, 2025
    Why my Thermo King Automobile Accessories multi-temp unit can't cool the entire trailer?
    • A
      Anthony SantosSep 1, 2025
      A multi-temperature unit may not have the cooling or heating capacity to maintain a specific temperature range throughout an entire trailer if it is being used to cool/heat a single temperature load.

Thermo King SLXi Spectrum Specifications

General IconGeneral
BrandThermo King
ModelSLXi Spectrum
CategoryRefrigerator
LanguageEnglish

Related product manuals