Thermo Scientific Wellwash - User Manual

Thermo Scientific Wellwash
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Thermo Scientific
Wellwash
User Manual
Rev. 1.1, Cat. No. N15777

Table of Contents

Questions and Answers

  • T
    Timothy BakerAug 18, 2025
    What to do if liquid is spilled during Thermo Scientific Laboratory Equipment operation?
    • K
      Kim WestAug 19, 2025
      If liquid is spilled during operation of your Thermo Scientific Laboratory Equipment, check the tubings and O-rings, and replace them if needed. Also, consider decreasing the well volume or shake speed.
  • R
    Robert MedinaAug 21, 2025
    How to fix Thermo Scientific Wellwash Laboratory Equipment when dispensing volume is too low or residual volume too high?
    • D
      David BensonAug 21, 2025
      To address low dispensing volume or high residual volume in your Thermo Scientific Laboratory Equipment, use the Maintenance > Clean > Soak wash head function. Clean or replace the tubing, and clean the wash head tips with the declogging tool or replace the wash head. Additionally, define the correct aspirate height.
  • D
    Dale RoseAug 23, 2025
    What to do if priming failed on Thermo Scientific Wellwash?
    • G
      Gregory ClaytonAug 23, 2025
      If priming fails on your Thermo Scientific Laboratory Equipment, check the tubings for correct installation and clogs, clean or replace them if necessary. Increase the priming volume, and ensure the corresponding buffer bottle is completely full. If the instrument hasn't been used for a while, use the Maintenance > Service > Boost prime option. Also, move the liquid bottles to the instrument level.
  • J
    Juan CruzAug 26, 2025
    Why is the wrong volume dispensed by my Thermo Scientific Wellwash Laboratory Equipment?
    • W
      wagnerbrianAug 26, 2025
      If your Thermo Scientific Laboratory Equipment is dispensing the wrong volume, check that the wash head is properly fitted and calibrate it. Ensure the venting holes in the liquid bottle caps are not covered. Check the step parameter and adjust it if needed. Calibrate the dispensing pump speed and check the ambient temperature.
  • E
    Edward CummingsAug 28, 2025
    How to fix Thermo Scientific Wellwash Laboratory Equipment when dispensing volume is too low?
    • O
      odonnellamberAug 28, 2025
      If the dispensing volume is too low in your Thermo Scientific Laboratory Equipment, calibrate the wash head and clean the liquid filters in the bottles. If the issue persists, it may indicate component failure, and you should contact authorized technical service.
  • S
    Shelly JonesAug 30, 2025
    What to do if tips are dripping on Thermo Scientific Wellwash?
    • M
      Matthew HowardAug 30, 2025
      If the tips are dripping on your Thermo Scientific Laboratory Equipment, check that the tubes and wash head plugs are properly fitted and that the tubings are intact. You can also apply silicone to the O-ring.
  • P
    Peggy LaneSep 1, 2025
    What to do if volume is too low with Thermo Scientific Wellwash?
    • J
      jennifer50Sep 1, 2025
      If the volume is too low with your Thermo Scientific Laboratory Equipment, change the wash head and clean or replace the tubing.
  • M
    Mrs. Joy SantosSep 3, 2025
    What to do if liquid is dispensed onto the plate carrier of Thermo Scientific Wellwash?
    • D
      dhughesSep 4, 2025
      If liquid is being dispensed onto the plate carrier of your Thermo Scientific Laboratory Equipment, check the layout and place the plate in the correct orientation required by the wash head configuration. Also, check the installed wash head and replace it with the correct one required by the layout and protocol.
  • D
    Dana SnowSep 6, 2025
    What to do if the wrong volume is aspirated by Thermo Scientific Laboratory Equipment?
    • J
      jose16Sep 6, 2025
      If the wrong volume is being aspirated by your Thermo Scientific Laboratory Equipment, connect the aspiration tube to the wash head and make sure you do not cover the venting holes in the bottle caps.
  • C
    Christian WolfSep 8, 2025
    What happens if plate is processed incorrectly or reagents are mixed in Thermo Scientific Laboratory Equipment?
    • W
      Wayne Smith DDSSep 8, 2025
      If the plate is processed incorrectly or reagents are mixed in your Thermo Scientific Laboratory Equipment, it may be due to a non-active valve leaking. This indicates component failure, and you should contact authorized technical service.

Summary

Safety Symbols and Markings

Symbols on Instrument

Symbols and markings found on the instrument's type label and itself.

Symbols in Documentation

Symbols and markings used within the user manual to convey warnings and information.

Installation

Unpacking

Procedures for safely unpacking the instrument.

Operating the Instrument

Interface Navigation and Controls

How to use the display, keypad, and primary buttons for operation.

Main Menu and Liquid Level Indicators

Using the Main menu and understanding liquid level indicators.

Running Protocols

General Protocol Execution

Step-by-step guide for running a wash protocol.

Protocol Setup

Filling bottles, starting protocols, and selecting strips.

Plate Loading and Run Control

Instructions for loading plates and managing runs.

Menus, Tabs, and Parameters

Settings Menu

Maintenance Menu

Cleaning Procedures

Overview and details of instrument cleaning processes.

Calibration Procedures

Steps for calibrating the instrument and wash head.

Protocol Management

Shutdown Procedure

Emergency Situations

Handling Abnormal Situations

Steps to take in case of operational abnormalities or spills.

Maintenance and Care

Routine Maintenance Schedule

A checklist for regular and preventive maintenance tasks.

Decontamination Procedure

Steps for decontaminating the instrument, especially after spills.

Technical Specifications

Safety Specifications

Troubleshooting Guide

Error and Warning Codes

List of error/warning codes and their suggested actions.

Common Instrument Issues

Table of symptoms, causes, and suggested actions for instrument problems.

Thermo Scientific Wellwash Specifications

General IconGeneral
TypeMicroplate Washer
BrandThermo Scientific
ModelWellwash
Liquid Level SensorsYes
Plate Type96-well microplates
CompatibilityStandard flat-bottom, U-bottom and V-bottom microplates
Manifolds8- or 12-well manifolds
Residual Volume< 2 µL/well
User InterfaceTouchscreen or software-controlled
Number of Wash BuffersUp to 3
ApplicationsELISA, cell-based assays
Wash ModesPlate wash, cell wash
Weight11.5 kg