18
NOTE: The evaporator coil and the water tank are one unit.
They cannot be separated. The following procedure assumes
that the pump along with its plumbing has been removed.
Disconnect unit from line voltage.
1. Recover refrigerant, if any remains.
2. Drain fluid from system.
3. Remove valve cores from both Shrader valves.
Tank Coil Assembly (TCA) replacement