EasyManua.ls Logo

Thies CLIMA Compact WSC10 - User Manual

Default Icon
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Weather Station Compact WSC10
Instructions for Use
4
.9042.00.00x
Softwareversion: V00.07 Stand: 02/2023
Dok. No. 022028/02/23
T H E W O R L D O F W E A T H E R D A T A
Question and Answer IconNeed help?

Do you have a question about the Thies CLIMA Compact WSC10 and is the answer not in the manual?

Summary

Safety Instructions

Environment

Documentation

Device Version

Application

Structure and Mode of Operation

Wind Speed and Direction

Details on how wind speed and direction are measured by the device.

Brightness Measurement

Explanation of how brightness is measured using photo sensors.

Twilight Measurement

How twilight is calculated from brightness sensor values.

Global Irradiance

Description of the sensor used for measuring global irradiance.

Precipitation Detection

Explanation of the capacitance measurement for precipitation detection.

Air Temperature

Information on the PT1000 measuring resistor for air temperature.

Time, Date, and Geostationary Data

How the device uses GPS for time, date, and location data.

Sun Position Calculation

Method for calculating the sun's position based on GPS data.

Humidity Measurement

Details on the hygro-thermosensor and humidity calculations.

Inside Temperature

Measurement of internal housing temperature using a silicon sensor.

GPS Receiver Details

Information on GPS receiver, RTC, and data accuracy.

Data Averaging

Configuration of averaging periods for meteorological readings.

Installation

Installation Site Selection

Guidelines for choosing the optimal location for the weather station.

Mounting Procedure

Step-by-step guide for mounting the weather station hardware.

Positioning and North Alignment

Instructions for orienting the station to geographic north.

Electrical Connection

Details on connecting the power supply and data cables.

Cable Disassembly

Procedure for safely disconnecting the supply and data cable.

Maintenance

Interface

THIES Command Interpreter

Using commands for configuration and data retrieval in THIES format.

MODBUS RTU Interpreter

Overview of MODBUS RTU communication and supported functions.

Data Telegrams

Description of data telegram formats, control characters, and separators.

MODBUS Functions

Supported MODBUS functions and exception responses.

Measuring Values (Input Register)

Mapping of measuring values to MODBUS register addresses.

Commands (Holding Register)

Examples of setting parameters via MODBUS holding registers.

Commands and Description

List and explanation of available commands for device configuration.

Command Al

Sets the averaging interval for wind speed and wind direction.

Command Cl

Selects the command interpreter (THIES or MODBUS RTU).

Command BR

Sets the baud rate for the serial communication interface.

Command DC

Configures the twilight calculation mode based on brightness values.

Command FB

Enables or disables the quick-start mode for the device.

Command HP

Sets the heating capacity for condensation protection.

Command ID

Sets the device identification number or MODBUS slave address.

Command KY

Sets or verifies the password for accessing protected parameters.

Command LC

Controls the green LED, indicating wind speed or darkness.

Command NC

Applies an offset to correct the north direction for wind measurement.

Command RD

Sets or queries the response delay for commands.

Command RS

Resets the microcontroller, specifying the cause of the last reset.

Command SF

Configures the frame format for serial communication.

Command SV

Reads the software version of the weather station.

Command TR

Initiates one-off transmission of a specific data telegram.

Command TT

Selects the automatic output of telegrams at a 1-second interval.

Command TZ

Sets the time zone for date and time output.

Technical Data

Dimension Drawing

Accessories (Optional)

EC-Declaration of Conformity

UK-CA-Declaration of Conformity

Thies CLIMA Compact WSC10 Specifications

General IconGeneral
Wind speed measuring range0 to 75 m/s
Wind direction measuring range0 to 360°
Humidity measuring range0 to 100% RH
Protection classIP66
Measuring principleUltrasonic for wind; capacitive for humidity
Measured variablesWind speed, wind direction, air temperature, relative humidity, air pressure, precipitation
Temperature measuring range-40 to +60 °C
Air pressure measuring range600 to 1100 hPa
OutputRS-485 (Modbus)
Operating temperature-40 to +60 °C
Dimensionsapprox. 150 mm