6.3.9 Command LC
<id>LC<parameter><CR> LED control
Access: Read / write.
Description: The command LC is used to specify the mode for control of the
green LED.
Parameter description:
Value range: 0 / 1
Initial value: 0
6.3.10 Command NC
<id>NC<parameter><CR> North correction of the wind direction
Zugriff: Read / write
Beschreibung: An offset for the wind direction in ° is specified with the
command NC. This can be used to correct the north direction.
Wertebereich: 0 … 360
Initialwert: 0
6.3.11 Command RD
<id>RD<parameter><CR> Response delay.
Zugriff: Read / write
Beschreibung: The RD command is used to query or set the response delay
between receiving a command and sending the response.
Parameter description: Delay in milliseconds e.g. 20 20[ms]
Wertebereich: 0 … 50
Initialwert: 20