Routethepowercable.
Wires(powersupply,antennacables)mustnotbeincontactwithanymobilepart.
4 - CONNECTING THE MOTOR
Safety instructions:
Cutoutelectricalpower(circuitbreakerinOFFposition)beforeperforminganyoperations.Theinstallation
mustbemadebyqualiedpersonnel.
Connectthepowercabletothemainsusingacableof2x0,75mm²min.
Important notes:
Thepowerlinemustbeusedexclusivelytopoweryourmotorisedshuttersandmustbeprotectedbya
fuse,circuitbreakerorresidualcurrentdevice(30mA).Compliancewithelectricitysafetyregulationsis
required.
EN
24
D - INSTALLATION
MOTORISED KIT WITH ARTICULATED ARMS
FOR SINGLE OR DOUBLE LEAF SHUTTERS
OFF
to the neutral
Conductor of
electric power
to the conductor
Phase electric
power
blue
brown