31EXPERT SETTINGS
EXPERT SETTINGS
REPLACING THE CARTRIDGE
To replace the complete cartridge with another model, please follow the steps below.
• Put on the needle guard, unscrew the headshell and pull it o the tone arm tube.
• pull o the four coloured cables from the pins on the cartridge and unscrew it.
• Screw the new pick-up into the headshell and connect the cables. Do not tighten the screws yet.
• Move the pick-up in the headshell until the overhang and zero crossings fit. You will need an adjustment
template for this.
• Tighten the screws.
Wiring diagram of the coloured cables:
Red = signal right
Green = ground right
White = signal left
Blue = ground left
If you replace the complete catridge, the tone arm must be readjusted as described above.