FREQUENCY DRIVE WIRING DIAGRAM (EP-16)
FREQUENCY DRIVE WIRING DIAGRAM
GFCI
BREAKER
GROUNDING
BAR
GREEN GROUND) CONNECT TO
GROUNDING BAR
WHITE (NUETRAL)
RED
BLACK
GROUND
POWER IN
220
LINE 1
POWER IN
220
LINE 2
POWER IN
BALBOA
CONTROL
GROUND
NOTE: THE POWER IN TO THIS CONTROL DOES NOT HAVE A COMMON LINE IN,
ONLY A GROUND. DO NOT HOOK A COMMON TO A POWER IN TERMINAL! THIS
WILL DAMAGE THE UNIT
TOUCHPAD
CONTROL
IMPORTANT: REQUIRED SIEMENS 60A GFCI CIRCUIT BREAKER TO OPERATE
THE TIDALFIT EP-16