Safety Information
SAFETY INFORMATION
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
AVOIDING THE RISK TO CHILDREN
DANGER:
• Extremecautionmustbeexercisedtopreventunauthorizedaccessbychildren.Toavoidaccidents,ensurethatchildrencannotusea
spa unless they are supervised at all times.
WARNING:
• Toreducetheriskofinjury,donotpermitchildrentousethisspaunlesstheyarecloselysupervisedatalltimes.
• Toreducetheriskofinjury,lowerwatertemperaturesarerecommendedforyoungchildren.Childrenareespeciallysensitivetohotwater.
DO:
• Makesureyoualwayslockthechildresistantlocksafterusingthespaforyourchildren’ssafety.EveryTigerRiver
®
spa is equipped with a
locking cover that meets the ASTM F1346-91 Standard for Safety Covers.
• Testthewatertemperaturewithyourhandbeforeallowingyourchildrentoenterthespatobesurethatit’scomfortable.Childrenare
especially sensitive to hot water.
• Remindchildrenthatwetsurfacescanbeveryslippery.Makesurethatchildrenarecarefulwhenenteringorexitingthespa.
DON’T:
• Allowchildrentoclimbontothespacover.
• Allowchildrentohaveunsupervisedaccesstothespa.
AVOIDING THE RISK OF ELECTROCUTION
RISK OF ELECTROCUTION
• Connectonlytoagroundedsource.
• Donotburythepowercord.Aburiedpowercordmayresultindeath,orseriouspersonalinjuryduetoelectrocutionifdirectburial-type
cable is not used, or if improper digging occurs.
• Agroundterminal(pressurewireconnector)isprovidedonthecontrolboxinsidetheunittopermitconnectionofaminimumNo.8AWG
(8.4 mm²) solid copper bonding conductor between this point and any metal equipment, metal water pipe, metal enclosures of electrical
equipment, or conduit within five feet (1.5 m) of the unit as needed to comply with local requirements.
WARNING:
• Toreducetheriskofelectricalshock,replaceadamagedcordimmediately.Failuretodosomayresultindeathorseriouspersonalinjury
due to electrocution.
• YourspaisprovidedwithaGroundFaultCircuitInterrupterforuserandequipmentprotection.Toensureproperoperationofthisimportant
safety device, test according to the following instructions per electrical configuration.
The GFCI is located at the end of the power cord. Before each use, with the unit operating, push the TEST button. The unit should stop
operating and the GFCI power indicator will go out. Wait 30 seconds and then reset the GFCI by pushing the RESET button. The GFCI
power indicator will turn on, restoring power to the spa. If the interrupter does not perform in this manner, there may be an electrical
malfunction and with it, the possibility of an electric shock. Disconnect the power until the problem has been corrected.
• Agroundterminalisprovidedontheterminalblock(TB-1,systemgroundterminal)locatedinsidethecontrolbox.Toreducetheriskof
electric shock, connect this terminal to the grounding terminal of your electrical service or supply panel with a continuous green, insulated
copper wire. The wire must be equivalent in size to the circuit conductors supplying the equipment. In addition, a bonding terminal
(pressure wire connector) is provided on the outside of the control box for bonding to local ground points. To reduce the risk of electric
shock, this connector should be bonded with a No. 8 AWG (8.4mm²) solid copper wire to any metal ladders, water pipes, or other metal
within 5 feet (1.5 m) of the spa to comply with local requirements. The means of disconnection must be readily accessible, but must be
installed at least 5 feet (1.5 m) from the spa.
• Yourspaisprovidedwithasuitablyratedcircuitbreakertoopenallungroundedsupplyconductors.