26
Description of Part Replacement Operation Timberline System
Binar Compact 5D/5B
1 Diagnosis 0.5
2 Glow Plug Replacement 0.25
3 Flame Detector Replacement 0.35
4 Air Blower Replacement 0.35
5 Fuel Pump Replacement 0.15
6 Control Unit/Sensor Board Replacement 0.3
7 Circulation Pump Replacement 0.5*
8 Fan Replacement 0.3*
9 Combusting Chamber Cleaning with Heater Removed 0.5
10 Heater Removal and Reinstallation 0.6*
11 Touch Panel Replacement 0.15
12 Timberline Control Box Replacement 0.15
13 Tank Sensor Replacement 0.15
14 High Limit Aquastat 0.25
15 120 V Relay Replacement 0.25
16 Timberline Tank Replacement 0.5**
17 External Air Temperature Sensor Replacement 0.25
18 Domestic Water Heat Exchanger Replacement 0.5* See Section 9
19 Heat Exchanger Sensor Replacement 0.15
20 Solenoid Valve Replacement 0.5*
21 Testing the System after Part Replacement 0.25
22 Purging and Testing the System after Coolant Part
Replacement
0.5
15. Manufacturers Warranty Continued
Warranty Part Replacement Labor Time