Timeguard NTT03 - NTT04 Voltage Free Wiring

Timeguard NTT03
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
S S
INOUT
N L
230V 50Hz
Mains Supply
6
NTT04 Only – Voltage Free Switching
e.g. 24V lighting circuit
Note: this device needs to be left to charge for
a minimum of 15 minutes once powered up,
before it will operate.
230V 50Hz Mains Supply
Live (Brown or Red) to L
Neutral (Blue or Black) to N
Load
Live Input (for voltage free output) S IN
Switch Live output
(to low voltage appliance) to S OUT
S S
INOUT
N L
Load
230V 50Hz
Mains Supply
230V 50Hz
Mains Supply