1. General Information
These instructions should be read carefully and retained for further reference
and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to the
Programmer is switched off and the circuit supply fuses are removed
or the circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or used for the
installation of this Programmer and install in accordance with the current
IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this Programmer is
fitted does not exceed the rating of the circuit cable, fuse or circuit breaker.
• To clean use a clean dry cloth only. Do not use any liquid cleaners.
3. Technical Specifications
• 230V AC 50 Hz
• This thermostat is of Class ll Construction and must not be earthed
• Switch Rating: 3(1)A
• Switch Type: Single pole, double throw (SPDT)
change over contacts
• Connection Type: 3 wire
• Installation Type: Surface mount with wall plate
• Micro Disconnection: Type 1.B control action
• Operating Temperature Range: 0°C to +40°C
• Programme: 5 day plus 2, or 7 day set by DIP switches
• Time Control Periods: 3 per day with copy function
• Clock Format: 12 hour AM/PM or 24 hour
• Summer/Winter Changeover: Day light saving, GMT or BST
• Holiday Mode: 0 to 31 day Programme suspension
• Boost Function: 1, 2 or 3 hour