menu
function
Windows
default
scope
remarks
P-01
Lift the brake speed
70
20-100
The larger the value, the faster the speed
P-02
Landing speed
70
20-100
The larger the value, the faster the speed
P-03
Lift the first part of the
brake for the deceleration
stroke
40
10-60
Start the to start slow stroke, unit: degree
P-04
The first part of the trip
40
10-60
Start the trip to slow down, in unit: degrees
P-05
Lift brake acceleration time
80
30-250
Speed to lift speed, in 0.01 seconds
P-06
Drop brake acceleration
time
80
30-250
Speed to closing speed, in 0.01 seconds
P-07
End speed of lifting gate
30
10-60
End of the brake lift at this speed in 10rpm
P-08
Landing end speed
30
10-60
End at this speed in 10rpm
P-09
horizontal position adjust
36
0-252
Fine-tune the horizontal position of the gate bar
P-10
vertical position adjust
36
0-252
Fine-tune the vertical position of the gate bar
P-11
Lift the second part of the
brake for the deceleration
stroke
18
0-252
Lift the second section of the brake deceleration stroke
P-12
The second section of the
stroke
18
0-252
The ated stroke of the second section
P-13
Resistance to the rebound
sensitivity adjustment
25
10-250
Resistance response time, in unit: 0.1s
P-14
Encounter resistance to
rebound strength
adjustment
40
10-80
The bigger the value, the stronger the value
P-15
Lift the gate and memory
function setting
0
0-1
The memory is off by default
P-16
Type of ground sensation
falling rod
0
0-3
0 means opening properly, 1 means closing immediately, 2
means the buzzer rings immediately, and 3 means the
buzzer rings immediately
P-17
No sense automatic
shutdown time
0
1-250
This feature is turned off by default in 1 seconds
P-18
Ground sensing delay rod
drop time
0
0-25
This feature is turned off by default in 1 seconds
P-19
Motor start-up strength
adjustment
50
10-80
The bigger the value, the stronger the value
P-20
Motor maximum strength
adjustment
70
30-90
The bigger the value, the stronger the value
P-21
Motor type / rotation
direction setting
0
0-5
Motor polarity and gate rotation direction
P-22
Remote control learning
0
0-200
Learn the remote control, the maximum number of 200
P-23
Find the initial position
speed
60
30-90
The upper and lower limits of this speed are measured in
rpm
P-24
RS485 Address
0
0-31
RS485 mailing address
P-25
RS485 Mode Settings
1
0-3
RS485 pattern
P-26
Motor positive and reverse
switch time
10
5-50
Unit: 0.1 seconds
P-27
Motor stop time
5
2-50
Unit: 0.1 seconds
P-28
Lift the gate first
0
0-1
Under the lock lift first mode, open first
P-29
The velocity PID parameter
is Kp regulation
100
50-250
The larger the value, the greater the speed adjustment
P-30
Automatic test mode
0
0-20
Automatic test interval, 0 is the normal operation
P-31
Number of remote control
0
0-200
Clear all learning remote controls
P-32
Restore the factory
parameter settings
0
0-1
Restore the default parameters