Range: 2-50, default: 5, unit: 0.1 seconds.To prevent the violent shaking of the
brake rod, the motor needs to slow down to zero within the set time to eliminate
the jitter.
P-28, gate lift is preferred
Range: 0-1, the default: 0. In some scenarios require invalid shutdown and stop
during lifting the rod.
0: In the process of lifting, closing and stop according to closing and shutdown.
1: In the process of lifting the lock, press to close, stop is invalid.It must
be put in place before working.
The P-29 speed PID parameter Kp setting
Range: 50-250, Default: 100. This parameter is used to adjust the magnitude of
speed changes over the same time interval.
P-30, automatic testing
Range: 0-250, default: 0, unit: seconds.The time interval of automatic testing,
being 0, indicates closing automatic testing for automatic testing and aging
testing.After the test is completed, set the parameter to 0 to remove the automatic
test.
P-31 to clear the remote control
After entering this menu item, the number of currently learned remote controls
is displayed. Press confirm key to clear all learned remote controls, and the number
of remote controls is displayed as 0.
P-32 restores the factory settings
Recovery of factory settings, all parameters use default settings, control board
default parameters can meet the most scenarios.If improper setting occurs during
setup, you can use the restore factory setting function.Display the "R-S" after
entering the recovery factory setting menu, clear all user Settings after
confirmation, display the "SYS" after clearing success, buzzer loudly and exit the
setting mode.
4.8 Functional schematic diagram
1. Schematic diagram of adjusting the horizontal and vertical positions by P-09 /
P-10