Range: 30-90, default: 70. The maximum allowable force when operated by the motor,
the greater the value, the greater the strength.
P-21 Motor type / direction of rotation
Value range: 0-5, default: 0. Because the pole logarithmic of the motor, the
deceleration series of the gate movement is different, the gate has the left and
right out of the pole.So this parameter is used for being compatible with various
types of motors and gates.0 and 1,2 and 3,4 and 5 are corresponding in pairs. When
the "lift / +" button gate lever is pressed, the choice of motor type and rotation
direction is correct, while the rotation direction of the motor should be
adjusted.Hino motor chooses between 0 and 1, Chengbang motor between 2 and 3, and
Tibang motor between 4 and 5.
P-22 Remote Control Learning
Entering the remote learning menu item shows the number of currently learned.Press
any key of the remote control, learn the successful buzzer long sound, and the
LED shows the number of learned remote control plus one, after learning a remote
control can continue to learn the next, the maximum support of up to 200 remote
control.If it is a learned remote control, the buzzer calls rapidly three times
continuously, suggesting that the remote control has been learned.After the study
is completed, press the confirmation key to exit. Then the successful remote
control will have a corresponding response in the normal working state.
The P-23 looks for the initial position and speed speed
Range: 30-90, default: 60. After the gate controller, find the upper and lower
limits at this speed.After the upper and lower limit learning is completed, enter
the normal working state.
P-24 Equipment RS485 Address
Range: 0-31, the default: 0. Device address for the RS485 communication period.
The P-25 device RS485 mode setting
Range: 0-3, Default: 1. The device enables the RS485 function for single or online
mode.The master-slave address must be set to the same in online mode.0 Single-alone
host mode in which the device actively uploads device status every 300ms, including
the received remote control status.1 For stand-alone slave mode, a query command
is required to obtain the device status.2 It is online host mode in which the host
is slave.3 For the online slave mode.
The P-26 motor has a positive and reverse switching time
Range: 5-50, default: 10, unit: 0.1 seconds.In order to prevent the impact of
reverse electric momentum on the motor by positive rotation switch, the motor needs
to slow down and then reverse accelerate.
P-27 motor stop time