parameter.For gates with rubber ring as a buffer, this value needs to be increased
to avoid squeezing the rubber ring with each opening.
P-11
This parameter sets a low speed uniform speed zone during the lift.During the lift,
at this angle, at P-07 until it is completely closed.
P-12
This parameter sets a uniform zone during the trip.During the trip, at this angle,
P-08 will end until it is completely closed.
P-13 meets resistance and rebound sensitivity
Range: 10-250, default: 25, in: 0.01 seconds.When the strength of resistance
exceeds the set value of P-14, the timing starts, and exceeds the set time, the
gate rebounds.
P-14 encountered resistance rebound strength
Range of 10-80, with a default of 40. The bigger the numbers, the bigger the numbers
are.This parameter works with P-13 resistance rebound sensitivity to determine
a rebound.If there rebound during normal shutdown, the two parameters P-13 and
P-14 should be increased.
P-15 lift gate memory function setting
Range 0-1, the default value: 0. In some application scenarios, the number of
opening closures and the number of ground sensing relay closures are consistent
to close the gate.This feature can then be enabled.The 0 is not enabled for the.
P-16 ground gate type
Range 0-1, the default value: 0. After the ground sense signal disappears, whether
to drop the switch immediately or wait until the switch is in place.0 Represents
the gate after lifting in place, 1 means immediately.
P-17 no land sense (start rod limited time) automatic closing time
Range: 0-255, default: 0, unit: seconds.After the gate is opened, if the car is
not detected after the time set by the parameter, the gate will be automatically
closed.If set to 0, the gate is open until the car passes by or the close button
is pressed.
P-18
Range: 0-25, default: 0, unit: seconds.After the ground sense signal disappears,
and then start the drop gate.
P-19 motor starting strength
Range: 10-80, default: 50. The start strength of the motor, the greater the value,
the greater the start strength.
P-20 motor maximum strength