TD80 Level Gauging and Overfill Prevention System Product Manual
Rev. 2, August 4, 2015/ TD80 Installation Page 25
TPM 001
Vehicle mounted tanks present another challenge to correct location of the probe. The
preferred location is the center of the tank, both across the width and length to minimize
measurement errors due to leveling of the vehicle.
Figure 2-3: Trailer Mounted Tank
2.3.2 Locating the Transmitter
Ensure sufficient clearance between the transmitter and tank top mounted fittings,
obstructions or manway. Provide at least 6” of clearance around the transmitter. Consider
the installation location for clearance of the large 1 ¾” wrench required to install the
probe and transmitter. These components must be sufficiently tightened for safe and
reliable operation.