Version 2.01 TS132/TS142/TS152 QIG
LONG AUX. LOCK OUTPUT
M2-6-1 Flash Lock output will activate for 30 seconds if buttons 1 and 4 are
pressed together on T96 style remotes OR button 4 THEN button 1
on T85 and T99 style remotes.
M2-6-2 Flashes Latched Lock output will activate until ANY other input is received
from the transmitter.
M2-6-3 Flashes Lock output will activate for 15 seconds if buttons 1 and 4 are
pressed together on T96A.
ACTIVE/PASSIVE ARM (TITAN SECURE FEATURES ON ONLY)
M2-7-1 Flash Passive ± Titan-Secure features and Starter disable will arm
Passively (See notes below).
M2-7-2 Flashes Active ± Titan-Secure features & Starter Disable will arm
only with the transmitter (Lock/Arm & Unlock/DisArm).
PASSIVE ARMING:
a. Turn ignition ON, then OFF and close the last door. After 30 seconds, the system will
arm and lock automatically (LAST DOOR ARMING). Note: The system will still arm
with lock function if programmed to this mode.
b. When alarm is disarmed, if Accessory (Key) is not turned on / doors are not opened,
30sec later, the system will be automatically Re-Arm and the doors will lock. (AUTO
RE-ARMING)
MENU 3 EXPLANATION
WAIT TO START LINE (GREY/BLACK)
This wire is foU'LHVHO(QJLQHV7KHZLUHFDQEHFRQQHFWHGWRD³:DLW7R6WDUW´ODPSDJORZ
plug, or manifold heater and will not allow the remote starter to crank (up to a maximum of 30
seconds) until the input is off allowing Glow Plugs or Manifold Heaters to sufficiently warm
up before cranking the engine.