EasyManua.ls Logo

Titan TS142 - Auxiliary Output Configuration

Titan TS142
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Version 2.01 TS132/TS142/TS152 QIG
M4-1-2 Flash Press and hold button 3 for 2 seconds, there will be a .75 second
pulse from the Blue Re-arm wire. Press and hold button 4 for 2
seconds, there will be a .75 second output pulse from the Green /
Black Dis-arm wire.
M4-1-3 Flash Press and hold button 3 for 2 seconds, there will be a 3.5 second
pulse from the Blue Re-arm wire. Press and hold button 4 for 2
seconds, there will be a 3.5 second output pulse from the Green /
Black Dis-arm wire.
M4-1-4 Flash Wires operate as default Re-arm and Dis-arm outputs. (Default)
R
ED/WHITE AS AUXILIARY OUT
M4-3-1 Flash Red / White Trunk release output will operate as a defrost output and
provide a .75 second pulse 30 seconds after the vehicle remote starts.
M4-3-2 Flash Red / White Trunk release output will operate as a drivers priority
output and provide a .75 second pulse with a second press of the
Unlock button on the remote. This second button press must be
within 5 seconds of the first for the output to happen.
This output takes precedence over negative park light switchover in
program M2-2. In other words if this output is programmed as
drivers door priority, polarity will be negative and the park light
output will go back to positive. At this point an installer would have
to use a relay for negative park lights.
M4-3-3 Flash Red / White Trunk release output operates with a 3.5 second output.
M4-3-4 Flash Red / White Trunk release output operates with a .75 second
output