ProPlex IQ One user manual version 1.6.8 122216
10
ROUTING SETUP
To change DMX routing settings, set individual port directions (IN or OUT) and select Art-Net universe for
each port. Art-Net universe is displayed in two formats decimal and hexadecimal (hex value is in brackets).
Use Left/Right to select port. To edit, press OK. Left selects direction field, right selects universe field.
Up/Down changes values. Press OK again to save changes made. To exit, press Right until “EXIT” appears,
then press “OK”.
LOAD CONFIGURATION
To load pre-defined configurations and reset device to its defaults:
1) Config 1Sets ports to inputs and sets universes 0 through 3 for each port.
2) Config 2Sets ports to outputs and sets universes 0 through 3 for each port.
3) Config 3User-configurable preset.
4) Defaults – Resets all device settings, including name and network configuration to defaults.
Default name is “ProPlex IQ One” and default IP is 2.1.1.10.
5) EXIT -- To exit from main Menu.
Use Left/Right to select configuration. To load, press OK and confirm by selecting YES and pressing OK
again. To exit, press Right until EXIT” appears, then press OK.
- DMX port 1 -
dir OUT univ= 1 ( 01 )
- Config 2 -
all OUT univ 0 - 3