Document Ref 942005-001 Rev 2 Page 3-5
Component Technical Manual TQP-HS for Fuel Dispensers
3.2.2 REDUCED FUEL FLOW
Replace the belt
NO
YES
Worn out pump
Bypass blocked
NO
YES
YES
External problem
upstream (refer
to section 4.5)
Is the pump unit
air tight? (refer to
section 4.4)
YES
NO
NO
NO
YES
Site configuration
headloss excessive
Filter clogged (refer
to section 4.6)
Find air entry
(refer to section 4.7)
REDUCED
FUEL FLOW
Has the drive
belt slackened?
Check
condition of
filters (hose,
PAS)
Adjust the
bypass (refer to
section 4.1)
Outlet pressure
>1.5 bar (refer
to section 4.1)
Is the pump
unusually
noisy?
High inlet
headloss >400
mbar (refer to
section 4.2)
Is the fuel
supply line air
tight?