8. Maintenance
Inspection and maintenance have to be done by instructed staff (competent).
The following maintenance intervals may be required subject to use and environment:
Water filter
clean / replace
every month
Pump motor
blow out the fan
every 6 months
Hoses and pipes
check tightness
every 6 months
Pump
check tightness
every 6 months
Bolts and seals
check tightness
every 12 months
Heat transfer oil (only valid for oil units)
change
every 4‘000 working hours
For extreme service there intervals must be shortened accordingly. For temperature control units
running with oil, the oil should be changed early, depending on the temperature. Comply with the
directives and recommendations of the oil manufacturer!
8.1. Inspection
Before starting the unit has to be checked the general condition of the temperature control unit, the
electrical connection and the tightness of the connections and hoses (including the consumer).
8.2. Cleaning
The temperature control unit has to be checked and cleaned periodically. Before maintenance the unit
has to be disconnected from the power supply.
8.3. Repair
Established defects must be repaired. To guarantee safety the unit must be repaired with original
TOOL-TEMP spare parts only.
WARNING
CAUTION
Waste oil has to be disposed as prescribed by law. Never let waste oil come
into the sewage system or soil.