12.2. List components and spare parts
Art.-Nr.
ELD-Code
Description
Comment
1
Fa0800326
Fa0800328
N 1
Digital temperature controller MP-888
Digital temperature controller MP-888
new
revised
2
Fa0900003
Fixing clips for controller MP-888
As a pair incl. straining
screw
3
Wa1000030
B 1
Temperature probe FeKo
cable length 1100 mm,
with angle plug 6.3 mm
4
Gb0700602
Gb0700601
Gb0700800
F 1
Motor protection relay 1.6 2.5A
Motor protection relay 1.0 1.6A
Motor protection relay 2.5 4.0A
575 600V 60Hz
200 230V 50/60Hz
5
Gl0200003
Gl0200001
F 7
Fuse 1A primary T1, 6.3 x 32 mm
Fuseholder big
Packing of 10 pieces
6
Gl0200000
Gl0200002
F 8
Fuse 1A secondary T1, 5 x 20 mm
Fuseholder small
Packing of 10 pieces
7
Gf0101200
F 10
Capillary pipe thermostat 80°C 370°C
8
Gf0100001
F 15
Level switch for level control
Unit off
9
Gf0100001
F 15/2
Level switch for level control
Auto. filling
10
Gl0400500
Gl0400610
F 23
F 47
Automatic cutout 20A, 3-poles
Automatic cutout 40A, 3-poles
200 240V 50/60Hz
11
Gl0200005
Gl0200006
F 27-/2
Fuse 6.3A, 6.3 x 32 mm
Fuse clip 6.3A, WK 10mm
2
(F27)
200 240V 50/60Hz
200 240V 50/60Hz
12
F 64
Sensor flow measurement
Type A (4.0…65 l/min)
Type B (1.5…35l/min)
13
Gk0300400
H 4/1
H 4/2
Lamp level control unit off
Lamp level control auto. filling
Double indication lamp
(yellow)
14
Gk0300100
H 6
Indication lamp motor overload (red)
15
Gk0300500
H 7
H 20
Lamp safety thermostat
Lamp temperature deviation control
Double indication lamp
(red)
16
Gg0300000
H 15
Horn
17
Gk0300100
H 63
Indication lamp flow control failure (red)
18
Gb0101210
K 1
Contactor 32A pump motor (main contactor)