Manual of instructions TT-390 16/35
For the cooling water connections it’s enough to use pressure- and temperature-resistant rubber
hoses. The tap water pressure has to be between 2,0 and 5,0 bar. We recommend to conduct the
water from the unit (cooling water outlet) to an unpressurized outlet.
WARNING
To ensure the operational safety is essential to use pressure- and
temperature-resistant hoses. Pressure-resistant up to 20 bar /
temperature-resistant up to +400°C.
For reason of safety, the cooling must always be connected!
NOTE
Process water filter on the return line reduces contamination in the unit,
which can cause a unit failure (pollution of the solenoid valve).
Mark and take down the maximum temperature for which the connections
are suitable!
5.3. Power supply
Compare supply voltage and frequency with the information on the serial plate. Verify the rating of the
preliminary fuse according to the information in the electrical diagram. Observe local laws during
set-up!
Power cable:
Phases
black / black / black
L1 / L2 / L3
Earth
yellow/green
PE
WARNING
The unit may only be connected by a competent electrician.
Ensure easy access to means for cutting the power supply (mains adapter or
mains connection), the access must be positioned in a distance of 0.6 and
1.9m above the access level.
Do not connect the power supply until the heating medium hoses are
connected!