16. SETTING-OUT MEASUREMENT
6. Press [OK] to return to <Key in coord>. Set the
next setting out point to continue setting out
measurement.
To find a point where a target cannot be directly installed, perform REM setting-out measurement.
"13.4 REM Measurement"
PROCEDURE
1. Install a target directly below or directly above the
point to be found. Then use a measuring tape etc.
to measure the target height (height from the
survey point to the target).
2. Select "Occupy setup" in <Setting out> to display
<Occupy setup>. If necessary, enter data for
Backsight setup.
"16.2 Distance Setting-out Measurement"
steps 2 to 3
16.4 REM Setting-out Measurement