Preparation for Use
Battery Installation
For battery placement or replacement instructions, see Maintaining Power Sources section,
page 28.
Instrument Set-up Procedure
Horizontal Rotation
1
Set the instrument on any smooth surface that is
within ±5° of true level. The RL-VH4DR/G2 auto-level
system will not function if the unit is placed more that
5° out of level. For best operation, it is recommended
that it be mounted to a tripod or the Topcon Wall
Mount Model 1D.
Slope can be set in both axes, X and Y. See “Setting
Slopes” section, page 21.
Horizontal
Leveling range