Line Control (manual vertical beam alignment)
1
Turn the leveling screw and position the bubble of the
level vial on the control panel in the center.
2
Press the Power control key to turn unit on. When auto-
leveling is complete, the laser beam will be emitted.
3
Press the plumb beam key to select the plumb beam
mode.
4
Move the instrument to align Point A with the center of
the laser.
5
Press the mode switch control to set your desired
rotation mode (scan mode / level sensor mode / laser
pointing mode).
6
Press the alignment control key once. Laser beam will
begin moving to the direction of the key pressed in
constant speed.
7
Press the Alignment Control key once more. Laser
beam gradient will stop.
8
Press either one of the Alignment Control keys to move the beam right or left until it is
precisely aligned to point B. The speed of laser beam movement will change according to the
duration of time the Alignment Control key is being pressed.
This mode can be used with the Remote Controller RC-40.
While an alignment control key is pressed the auto-leveling beam shut-off will not
operate.