8. CHANGING OPERATING PARAMETERS
The standard (default) setting for several operating parameters of the TP-L5 can be changed by
the user. This table below lists the operating parameters that can be changed, the stand default
setting and optional settings for each one.
8.1 Operating Parameters
Functions Parameter
Options
[default]
Description
ON/OFF of
enlarged display
of the level vial
indicator
R-TILT DISPLAY
(level vial indicator)
DISP 1: default OFF
When this parameter is set to ON, the level
vial indicator is enlarged when the
instrument is off and the power key is first
pressed.The power key must be pressed
again to turn instrument on.
DISP 2: default ON
The level vial indicator enlarges to fill the
display anytime the TP-L5 is tilted.The
display returns to normal when the
instrument is properly positioned or when
any other control key is pressed.
DISP1 ON/ [OFF]
DISP2 [ON] /OFF