11. TROUBLESHOOTING
76
The charging lamp of
the internal battery
BT-53Q is blinking
slowly when
connected to the DC-
12V external battery.
(Error blinking)
1) The charging temperature is out of
range.
2) The battery BT-53Q is completely
discharged.
1) Recharging should take place in
the temperature range of 10 to
35
°C (50 to 95°F).
2) Continue the charging for 30
minutes.
If the lamp changes to red light
up mode, the battery is normal.
If the lamp continues green
blinking, battery is faulty and
must be replaced. Always
properly dispose old battery.
Conditions Causes Countermeasures