EasyManua.ls Logo

Topens AT602 - User Manual

Topens AT602
27 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Dual Swing Gate Opener
User’s Manual
Model:
TOPENS Website
http://www.topenstool.com/
VER 20a
AT602
Please read and follow all warnings, precautions and instructions before
installation and use.
Never connect the solar panel to the control board directly to charge the battery.
Periodic checks of the opener are required to ensure safe operation.
Save this manual.
C030472
Question and Answer IconNeed help?

Do you have a question about the Topens AT602 and is the answer not in the manual?

Overview

This document is the User's Manual for the TOPENS Dual Swing Gate Opener, model AT602.

Function Description:

The TOPENS AT602 is a dual swing gate opener designed for vehicular swing gates (Class I). It automates the opening and closing of gates, offering both pull-to-open and push-to-open installation types. The system is equipped with an obstruction sensing feature, causing the opener to automatically reverse direction and stop if an obstruction is encountered. It supports both single and dual gate running modes and can be integrated with various accessories for enhanced functionality and safety.

Important Technical Specifications:

  • Model: AT602
  • Input: 110V~120V/60Hz or 220~240V/50Hz
  • Motor Voltage: 24VDC
  • Power: 2×50W
  • Current: 2A
  • Actuator Speed: 16mm/s (0.6 in/s)
  • Max. Actuator Travel: 385mm (15.2 in)
  • Ambient Temperature: -20°C ~ +50°C (-4°F to 122°F)
  • Protection Class: IP44
  • Gate Capacity (per actuator):
    • 300kg (660lbs) for gate length 1.2-1.8m (4-6')
    • 250kg (550lbs) for gate length up to 2.4m (8')
    • 200kg (450lbs) for gate length up to 3m (10')
    • 150kg (330lbs) for gate length up to 3.6m (12')
    • 100kg (220lbs) for gate length up to 4.3m (14')
    • 70kg (150lbs) for gate length up to 4.8m (16')
    • 50kg (100lbs) for gate length up to 5.5m (18')

Usage Features:

  • Soft Start and Soft Stop: Ensures smooth operation and reduces wear on the gate and opener.
  • Emergency Release Key: Allows manual operation in case of power failure.
  • Dual/Single Gate Running Mode: Configurable for one or two gates.
  • Adjustable Opening/Closing Interval: Allows setting a delay between the master and slave gate in dual gate mode.
  • Obstruction Detection: Stops during opening and reverses during closing if an obstruction is detected.
  • Adjustable Auto-Close: Built-in timer (0-99 seconds) for automatic gate closing.
  • Digital Display: Indicates running status and setting menu for easy configuration.
  • Electromagnetism Limit: Reliable limit switches for easy adjustment.
  • Compatibility with Accessories: Can be equipped with a wide range of optional accessories such as remote controls, wireless keypads, photocell beam systems, warning lights, and solar charging kits.
  • Remote Control Operation: Each remote has four buttons (A, B, C, D) and can be programmed to operate up to 4 sets of TOPENS swing gate openers or a combination of swing and sliding gate openers.
  • Wireless Keypad Programming: Allows operation with a programmable password.
  • Control Board Settings:
    • Single/Dual Gate Set (P1): Configures for single Actuator 1, single Actuator 2, or dual actuator mode.
    • PUSH TO OPEN/PULL TO OPEN Set (P2): Configures the gate opening direction.
    • Open Interval between Master and Slave Gate (P3): Adjustable from 0-9 seconds.
    • Close Interval between Master and Slave Gate (P4): Adjustable from 0-9 seconds.
    • Obstruction Sensitivity/Stall Force (P5, P6): Adjustable in 9 levels (1-9) for each gate opener.
    • Max Motor Running Time (MRT) (P7, P8): Adjustable from 1-50 seconds for each motor.
    • Safety Photocell Beam System (PBS) (P9): Enables or disables the photocell function (works only when the gate opener is closing).
    • Automatic Closing Time (PA): Adjustable from 1-99 seconds; "00" disables auto-close.
    • Period of Soft Start (Pb): Adjustable from 1-9 seconds.
    • Fast Running Period (FRP) (PC): Adjustable from 1-28 seconds to achieve soft stop.
    • Return to Factory Set (Pd): Resets all data to factory defaults.

Maintenance Features:

  • Regular Cleaning and Lubrication: Wipe the actuator shaft with a clean, dry cloth and apply silicone spray every 4-6 weeks, especially in cold climates, to reduce friction and prevent freeze-up.
  • Hinge Checks: Regularly inspect gate hinges to ensure smooth and free swinging; grease if needed.
  • Installation Checks: Periodically check hardware and posts for shifts; adjust brackets or tighten hardware as necessary.
  • Clearance Maintenance: Keep the area around the gate free of objects that could obstruct its movement.
  • Malfunction Inspection: Perform inspection and service anytime a malfunction is observed or suspected.
  • Voltage Verification: Use a digital voltmeter to verify that incoming voltage is within ten percent of the opener's rating.
  • Force and Sensitivity Adjustments: Refer to instructions for checking and adjusting gate force and sensitivity.
  • Troubleshooting Guide: Provides solutions for common issues such as opener not running, opener powering up but not running, gate stopping immediately after starting, gate opening but not closing, gate ignoring limit switches, and gate opening/closing/stopping on its own.

Topens AT602 Specifications

General IconGeneral
BrandTopens
ModelAT602
CategoryGate Opener
LanguageEnglish

Related product manuals