Instructions for Use TORMAX iMotion 1301/1301.S /1302.KI /1401 T-1305 en 13
4.7 Automatic System Monitoring
The control system monitors the safety sensors by a cycle of active tests. The control system also
conducts continuous internal system tests. If a safety-related component should fail, the system auto-
matically switches into a safe condition. At the same time the fault number is displayed on the user
interface. You can find further information on this subject in chapter 6.
4.8 Electric Lock u
The system can be locked in the closed position by means of an electric lock u.
4.9 Operation in the Event of a Power Failure
Depending on the equipment installed, the following functions are possible:
– Controlled closing using the integral spring. The door can be opened manually by means of the door
handle (unlocking).
The door then closes again in a controlled manner using the integral spring.
– Controlled opening using the integral spring. The door remains open.
– Continued operation for a certain period in the current operating mode by means of a battery unit u.
– Unlocking and opening of the door from outside by means of a key switch and the battery unit u.
The closing sequence is maintained in double-leaf door systems by the use of a mechanical door
coordinator.