EasyManua.ls Logo

Tornado 98103 - Troubleshooting

Tornado 98103
11 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
TROUBLESHOOTING
MOTORS NOT RUNNING
LOSS OF VACUUM SUCTION
SPRAY JET NOT FUNCTIONING PROPERLY
BRUSH NOT FUNTIONING PROPERLY
CAUSE SOLUTION
1) Power not reaching main switch. 1) Check power supply. Check fuses/circuit
breaker.
Contact service center.
2) Defective power cord. 2) Contact manufacturer or service center.
3) Faulty switches or wiring. 3) Contact manufacturer or service center.
4) Blown fuse or tripped circuit breaker. 4) Reset circuit breaker according to operating
instructions or replace fuse if qualified.
5) Problem with brushes, field windings, or
armatures. (vacuum or brush motor)
5) Repair or replace defective part.
6) Reset switch on back. 6) Push reset switch.
CAUSE SOLUTION
1) Vacuum head blocked. 1) Visually inspect and clear blockage.
2) Hose blocked. 2) Visually inspect and clear blockage.
3) Recovery tank not sealed properly. 3) Check tank for damage or adjust for proper
fit.
CAUSE SOLUTION
1) Belt broken. 1) Replace belt.
2) Brush jammed. 2) Visually inspect and clear blockage.
3) Brush pulley broken. 3) Replace pulley.
CAUSE SOLUTION
1) Jet blocked. 1) Visually inspect and clean according to
operating instructions.
2) Solution filter blocked. 2) Visually inspect and clean according to
operating instructions.