GeneralRunandTransportProblems(continued)
Problem
PossibleCauses
Theengineshutsoffduringtheoperation(theoperatorsitting
ontheseat).
Theoperatorisnotinthecenteroftheseat(theseatswitch
isnotpressed).
Theenginetemperatureisexcessive(above115°C/240°F).
Theenginehightemperatureshutdownswitchisdamaged.
Themachineisoperatedonaslopewithalowfuellevel.
Theparkingbrakeisengagedortheparkingbrakeswitch
isdamaged.
Thekeyswitchisdamaged.
Theseatswitchisdamaged.
Theseatswitchwiringisloose,corroded,ordamaged.
ThefusesF1-1,F1-2,F1-3,and/orF1-4are/isdamaged;
refertoFuses(MachineSerialNumberbelow400000000)
(page6–22)orFuses(MachineSerialNumberabove
400000000)(page6–23).
Wiringtotheruncircuitcomponentsisdamagedor
disconnected;refertoWiringSchematicsinAppendixA
(pageA–1).
Thefuelpumpisdamaged.
TheStandardControlModuleisdamaged.
Thebatterydoesnotcharge.
Aloose,corroded,orbrokenwire(s)existinthecharging
circuit;refertotheElectricalSchematicsinAppendixA(page
A–1).
Theenginealternatorbeltislooseordamaged.
Thealternatorisdamaged.
Thebatteryisdamaged.
Thefusiblelinkharnessattheenginestartermotoris
damaged.
ThePTOclutchdoesnotengage.ThesystemfuseF1-1(15A)orF1-3(10A)isopen;refer
toFuses(MachineSerialNumberbelow400000000)(page
6–22)orFuses(MachineSerialNumberabove400000000)
(page6–23).
ThelogicpowerfuseF1-4(2A)isopen.
Thefuseblockisdamaged.
ThePTOswitchisdamaged.
ThePTOlatchrelayisdamaged.
Theelectricclutchwiringisloose,corroded,ordamaged.
Theelectricclutchisoutofadjustmentordamaged.