EasyManua.ls Logo

Toro 30308 - High Temperature Shutdown Switch

Toro 30308
508 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HighTemperatureShutdownSwitch
g226811
Figure154
1.Hightemperatureshutdownswitch(dieselengine)
g230992
Figure155
1.Hightemperatureshutdownswitch(gasolineengine)
Thehightemperatureshutdownswitch(Figure154orFigure155)isattached
tothewaterpumphousingontheengineandhasablue/whitewireattachedto
it.Thisswitchisnormallyopenandcloseswhenenginecoolanttemperature
reachesapproximately115°C(240°F).Theclosedswitchprovidesaninputto
theStandardControlModule(SCM).
ThisinputcausestheSCMhightemperatureshutdownLEDtoilluminateand
thecuttingdecktoshutdown.Thehightemperatureshutdownswitchand
circuitwiringshouldbetestedasaSCMinputbeforeperformingthefollowing
testingprocedure.
TestingtheHighTemperatureShutdownSwitch
1.Parkthemachineonalevelsurface,lowerthecuttingdeck,shutoffthe
engine,settheparkingbrake,andremovethekeyfromthekeyswitch.
2.Unlatchthehoodandraiseit.
Groundsmaster
®
3280-D/3320
Page6–55
ElectricalSystem:TestingtheElectricalComponents
05138SLRevB

Table of Contents

Other manuals for Toro 30308

Related product manuals