Figure 51
1. Fuel pre-lter
3. Slide the hose clamps onto the ends of the fuel
lines . Push the fuel lines onto the fuel filter
and secure them with the hose clamps . Be sure
that the ar ro w on the side of the filter points
to w ard the injection pump .
Bleeding Air from the
Injectors
1. Loosen the pipe connection to the Number
1 injector nozzle and holder assembly at the
injection pump ( Figure 52 ).
Figure 52
1. Number 1 injector nozzle
2. Mo v e the throttle to the F ast position.
3. T ur n the k ey in the ignition switc h to the Star t
position and w atc h the fuel flo w around the
connector . T ur n the k ey to the Off position
when solid flo w is obser v ed.
4. Tighten the pipe connector securely .
5. R e peat the procedure on the remaining nozzles .
Electrical System
Maintenance
Activating, Charging, and
Connecting the Battery
Warning
CALIFORNIA
Pr oposition 65 W ar ning
Batter y posts, ter minals, and r elated
accessories contain lead and lead
compounds, chemicals kno wn to the State of
Calif or nia to cause cancer and r epr oducti v e
har m. W ash hands after handling .
Note: If the batter y is not filled with electrolyte
or acti v ated, bulk electrolyte with 1.260 specific
g ra vity m ust be purc hased from a local batter y
supply outlet and added to the batter y .
1. Raise the seat and secure it with the prop rod.
2. R emo v e the batter y co v er ( Figure 53 ).
Figure 53
1. Battery cover
3. R emo v e the filler caps from the batter y
( Figure 54 ) and slo wly fill eac h cell until
electrolyte is just abo v e the plates .